Key takeaways
- Mounting style. Horizontal 1U or 2U units take up rack space but are easy to view and reach; 0U vertical units mount along the rear posts and free up horizontal slots for servers and switches.
- Outlet count and type. Most server and network gear uses C13 or C14 inlets, so confirm the PDU offers enough C13 outlets, plus any C19 outlets needed for higher-draw equipment.
- Input plug and amperage. Check the PDU’s input plug type (standard NEMA 5-15P, a twist-lock L5-20P, or a hardwired connection) and confirm it matches the available circuit and its rated amperage.
- Switched versus unswitched versus metered. Unswitched units simply distribute power; switched units let someone power-cycle individual outlets locally or remotely; metered units add current and sometimes voltage readings for monitoring load.
- Network management. Networked PDUs typically add a web interface or SNMP support so administrators can check status and control outlets without being on site.
- Surge protection and circuit breaker. A built-in breaker protects against overload, and some units add surge suppression, though the maker’s manual should state the specific protection level.
- Cord length and routing. Rear-mounted or vertical units need enough cord length to reach the room’s power source without excessive slack cluttering the cabinet.
A basic 1U rack-mount power bar with 8 to 10 outlets and a front switch suits a small home-lab or network cabinet, while a metered or network-managed rack PDU with per-outlet control is the better pick for a server room where administrators need to monitor load or remotely cycle power on individual devices.
What a Rack Mount Power Bar Is
A rack-mount power bar, also called a rack PDU (power distribution unit), spreads a single incoming power feed across multiple outlets arranged to fit a 19-inch rack. Unlike a household power strip, rack PDUs are built to mount horizontally in 1U or 2U of rack space, or vertically along the rear rails in 0U configurations that save horizontal slots for other equipment. Features range from a basic unswitched strip with a circuit breaker up to networked units that report load and let administrators turn individual outlets on or off remotely.
What to Look For Before You Buy
- Mounting style. Horizontal 1U or 2U units take up rack space but are easy to view and reach; 0U vertical units mount along the rear posts and free up horizontal slots for servers and switches.
- Outlet count and type. Most server and network gear uses C13 or C14 inlets, so confirm the PDU offers enough C13 outlets, plus any C19 outlets needed for higher-draw equipment.
- Input plug and amperage. Check the PDU’s input plug type (standard NEMA 5-15P, a twist-lock L5-20P, or a hardwired connection) and confirm it matches the available circuit and its rated amperage.
- Switched versus unswitched versus metered. Unswitched units simply distribute power; switched units let someone power-cycle individual outlets locally or remotely; metered units add current and sometimes voltage readings for monitoring load.
- Network management. Networked PDUs typically add a web interface or SNMP support so administrators can check status and control outlets without being on site.
- Surge protection and circuit breaker. A built-in breaker protects against overload, and some units add surge suppression, though the maker’s manual should state the specific protection level.
- Cord length and routing. Rear-mounted or vertical units need enough cord length to reach the room’s power source without excessive slack cluttering the cabinet.
Picks by Tier
Budget: Basic Unswitched Strips
Simple rack PDUs with a fixed bank of C13 outlets, a circuit breaker, and no remote features cover a small home lab or network closet at low cost. Brands with long-running rack power lines, including Tripp Lite and CyberPower, sell basic unswitched 1U and 0U strips in this class.
Mid-Range: Switched PDUs with Local Control
Switched units add individual outlet control, usually through a front-panel interface or buttons, letting someone power-cycle a single device without unplugging it. This tier suits a small business server room where remote management is not required but the ability to reset a hung device without walking behind the rack is useful.
Premium: Networked and Metered PDUs
Premium rack PDUs add network connectivity, per-outlet or per-bank metering, and remote on/off control through a web dashboard or SNMP. Eaton, APC, and CyberPower all list networked PDU lines with these features. These suit colocation racks, data closets without daily on-site staff, or any environment where load monitoring and remote control justify the added cost.
At a Glance
| Tier | Best For | Key Stated Specs | Limits |
|---|---|---|---|
| Basic unswitched strip | Home labs, small closets | Fixed C13 outlet bank, circuit breaker | No remote control or monitoring |
| Switched PDU | Small server rooms with on-site staff | Local individual outlet control | No remote network access |
| Networked metered PDU | Colocation, unattended racks | Web/SNMP control, per-outlet load data | Highest cost; needs network setup |
Pick This If…
| Situation | Recommended Tier |
|---|---|
| You just need to plug in several devices in a small rack | Basic unswitched strip |
| You occasionally need to reset a device without unplugging it | Switched PDU with local control |
| Your rack sits in a remote site or unattended room | Networked metered PDU |
| You need to track power draw for capacity planning | A metered PDU with per-outlet or per-bank readings |
Fit and Compatibility Notes
Measure the rack’s usable depth and rail spacing before ordering, since 0U vertical units need clear space along the rear posts and horizontal 1U or 2U units need a free slot in the front or rear rails. Count every device’s inlet type before choosing outlet counts, since mixing C13 and C19 inlets in the same rack is common with high-draw equipment like blade servers or storage arrays. Confirm the input plug matches an available outlet or circuit, and avoid daisy-chaining multiple power strips, which the manufacturer’s manual typically warns against due to overload risk. For any new dedicated circuit or hardwired PDU installation, use a licensed electrician to meet local code.
Alternatives Worth Considering
A rack-mount UPS with built-in outlets can combine battery backup and power distribution in one unit for smaller racks that do not need a separate PDU. Individual plug-in smart outlets, while not rack-specific, can add remote control to a budget strip for a home lab on a tight budget. For racks needing true redundancy, two independent PDUs fed from separate circuits, paired with dual-power-supply equipment, can offer more resilience than a single PDU alone.
Frequently Asked Questions
What is the difference between a rack PDU and a regular power strip?
Rack PDUs are built to mount directly into a 19-inch rack’s rails or rear posts, with outlet spacing and connector types suited to server and network gear, while household power strips are designed for general use and do not mount into rack hardware. Rack PDUs also more commonly include features like metering or remote switching aimed at data center use.
How many outlets do I need on a rack PDU?
Count every device needing an independent power connection, add a few spare outlets for future equipment, and check whether any devices need C19 rather than C13 outlets. Running a PDU at its absolute maximum outlet count immediately leaves no room for growth.
Can I daisy-chain two power strips to get more outlets?
Most manufacturers advise against daisy-chaining power strips or PDUs, since it can exceed the rated amperage of the upstream unit and create an overload or fire risk. Choosing a PDU with enough outlets for current and near-future needs avoids this situation.
Do I need a networked PDU if I visit the rack daily?
If someone is on site regularly and can physically reset or check equipment, a basic or switched PDU without network features may be sufficient. Networked and metered PDUs add the most value when the rack is in a remote location or checked infrequently.
What is the difference between 0U and 1U mounting?
0U PDUs mount vertically along the rear rails and do not use any horizontal rack unit space, while 1U units occupy a full horizontal slot in the front or rear rails. 0U designs free up more usable rack space but may be harder to view or reach without removing rear panels.
How do I know if my PDU is overloaded?
Metered PDUs display current draw directly, while unmetered units rely on a circuit breaker tripping as the only overload signal. Calculating the combined rated power draw of all connected devices against the PDU’s stated maximum amperage before plugging everything in helps avoid surprises.
Can I mix a rack transfer switch and a rack power bar in the same cabinet?
Yes; a common setup pairs a transfer switch that selects between two power sources with one or more PDUs that distribute the selected power to individual devices, since the two serve different purposes. Confirming the transfer switch’s output matches the PDU’s input plug and amperage rating keeps the combination within its intended limits.
How do I maintain a rack PDU over time?
Routine care mostly involves keeping vents and connectors free of dust, periodically checking that cords are seated firmly, and testing any circuit breaker or reset function as described in the manual. Networked units may also need occasional firmware updates from the manufacturer to maintain security and feature support.